Features: high frequency load voltage, 30A under continuous DC, small size, low and stable contact resistance, low power in RF circuit, two optional installation methods, flange type and bolt type, bolt type or welded high-voltage connector, simple wiring, replaceable coil, so that the product functions can be diversified, meeting or exceeding mil-r-83725 standard. For load switch application, please consult the factory!
Relay rated parameters
Company
GT24C
GT24T
Contact code
C
contact form
SPDT
Maximum test voltage (leakage current not exceeding 15 μ A. DC or 60Hz)
kV Peak
twelve
twelve
Maximum operating voltage, contact to base (leakage current not exceeding 15 μ A)
DC or 60Hz
kV Peak
eight
eight
2.5MHz
kV Peak
five
16MHz
kV Peak
three
32MHz
kV Peak
one
Maximum continuous load current
DC or 60Hz
Amps
thirty
thirty
2.5MHz
Amps
eighteen
16MHz
Amps
nine
32MHz
Amps
five
Coil breakdown voltage (60Hz, AC effective value)
V
five hundred
five hundred
Contact capacitance
Between open contacts
pF
zero point five
zero point five
Contact to ground
pF
one
one
Maximum contact resistance (1a, 28vdc)
ohms
zero point zero two five
zero point zero two five
Maximum working time
ms
fifteen
fifteen
Maximum release time
ms
nine
nine
Mechanical life
Cycles
1 million
Nominal weight
g (oz)
84(3)
Vibration frequency (sinusoidal, 55~500 Hz, peak)
G's
ten
Impact level (11ms, half sine wave, peak)
G's
fifty
Operating ambient temperature range
℃
-55~+125
Coil parameters
Nominal Voltage VDC
twelve
twenty-six point five
one hundred and fifteen
two hundred and twenty
Maximum pull in Voltage VDC
eight
sixteen
eighty
one hundred and fifty
Release Voltage VDC
. 5-5
1-10
5-50
25-90
Coil resistance (Ω± 10%)
forty-eight
one hundred and eighty
two thousand and nine hundred
three thousand and three hundred
*The above data are measured at 25 ℃ and sea level