GT24 series vacuum relay -12kv

GT24 series vacuum relay -12kv

Model No.︰GT24系列真空继电器-12k

Brand Name︰GTVAC

Country of Origin︰China

Unit Price︰CNY ¥ 520 / pc

Minimum Order︰1 pc

Inquire Now

Product Description

Features: high frequency load voltage, 30A under continuous DC, small size, low and stable contact resistance, low power in RF circuit, two optional installation methods, flange type and bolt type, bolt type or welded high-voltage connector, simple wiring, replaceable coil, so that the product functions can be diversified, meeting or exceeding mil-r-83725 standard. For load switch application, please consult the factory!
Relay rated parameters
Company
GT24C
GT24T
Contact code
C
contact form 
SPDT
Maximum test voltage (leakage current not exceeding 15 μ A. DC or 60Hz)
kV Peak
twelve
twelve
Maximum operating voltage, contact to base (leakage current not exceeding 15 μ A)
DC or 60Hz
kV Peak
eight
eight
2.5MHz
kV Peak
five
16MHz
kV Peak
three
32MHz
kV Peak
one
Maximum continuous load current
DC or 60Hz
Amps
thirty
thirty
2.5MHz
Amps
eighteen
16MHz
Amps
nine
32MHz
Amps
five
Coil breakdown voltage (60Hz, AC effective value)
V
five hundred
five hundred
Contact capacitance
Between open contacts
pF
zero point five
zero point five
Contact to ground
pF
one
one
Maximum contact resistance (1a, 28vdc)
ohms
zero point zero two five
zero point zero two five
Maximum working time
ms
fifteen
fifteen
Maximum release time
ms
nine
nine
Mechanical life
Cycles
1 million
Nominal weight
g (oz)
84(3)
Vibration frequency (sinusoidal, 55~500 Hz, peak)
G's
ten
Impact level (11ms, half sine wave, peak)
G's
fifty
Operating ambient temperature range

-55~+125
Coil parameters
Nominal Voltage VDC
twelve
twenty-six point five
one hundred and fifteen
two hundred and twenty
Maximum pull in Voltage VDC
eight
sixteen
eighty
one hundred and fifty
Release Voltage VDC
. 5-5
1-10
5-50
25-90
Coil resistance (Ω± 10%)
forty-eight
one hundred and eighty
two thousand and nine hundred
three thousand and three hundred
*The above data are measured at 25 ℃ and sea level

Specifications︰ Relay rated parameters Company GT24C GT24T
Contact code C
Contact form SPDT
Maximum test voltage (leakage current not exceeding 15 μ A. DC or 60Hz) kV Peak twelve twelve
Maximum operating voltage, contact to base (leakage current not exceeding 15 μ A) DC or 60Hz kV Peak eight eight
2.5MHz kV Peak five
16MHz kV Peak three
32MHz kV Peak one
Maximum continuous load current DC or 60Hz Amps thirty thirty
2.5MHz Amps eighteen
16MHz Amps nine
32MHz Amps five
Coil breakdown voltage (60Hz, AC effective value) V five hundred five hundred
Contact capacitance Between open contacts pF zero point five zero point five
Contact to ground pF one one
Maximum contact resistance (1a, 28vdc) ohms zero point zero two five zero point zero two five
Maximum working time ms fifteen fifteen
Maximum release time ms nine nine
Mechanical life Cycles 1 million
Nominal weight g (oz) 84(3)
Vibration frequency (sinusoidal, 55~500 Hz, peak) G's ten
Impact level (11ms, half sine wave, peak) G's fifty
Operating ambient temperature range ℃ - 55~+125

Advantages︰ Features: high frequency load voltage, 30A under continuous DC, small size, low and stable contact resistance, low power in RF circuit, two optional installation methods, flange type and bolt type, bolt type or welding type high-voltage connector, simple wiring, replaceable coil, so as to diversify product functions, meeting or exceeding mil-r-83725