Home
Product Catalog
Vacuum Relays Capacitor
DWC-series Electric Septic Cha
Glass TRIODE
HV Relay (Vacuum Relay)
company profile;
VACUUM TRIGGER TUBE
Documents
News
Contact Us

Product Catalog 

GT80/120 Vacuum Relays

  • GT80/120 Vacuum Relays
  • GT80/120 Vacuum Relays
  • GT80/120 Vacuum Relays
  • GT80/120 Vacuum Relays
Model No.︰GT80/120型
Brand Name︰GTVAC
Country of Origin︰China
Unit Price︰-
Minimum Order︰10 pc
Share on:

 Total 120 Related Items 
Prev5556575859Next

Product Description

1. The relay is installed vertically.
2. After the relay passes the acceptance, general inspection must be carried out before installation, mainly including: the appearance should be clean without pollution and damage; Coil resistance test; High voltage test. To ensure reliable conversion and personal safety.
3. The high-voltage lead of the electrode shall be flat, wide and soft, and it is best to use silver plated copper strip to ensure that the lead inductance has little influence, the electrical contact is good, and the heat dissipation effect is good.
4. The relay usually generates electric arc during "thermal" conversion, and the ionized gas or metal vapor from the contact may cause flash or breakdown. In order to enable the product to cut off higher power and avoid destructive breakdown, the relay shall be connected to the load ground terminal as far as possible
5. After the relay is stopped accidentally for a period of time, there will be false "air leakage", which is due to the release of a small amount of gas adsorbed on the inner surface of the relay. At this time, it is allowed to remove it by high-pressure treatment, that is, before the relay is installed into the system, a simple high-voltage test will be carried out.
Note: during high-voltage treatment, when the voltage is greater than 15kV, X-rays will be generated, and the relay must be shielded with a lead plate greater than 1.6mm thick.
6. Since the working voltage of the relay is generally high, it is recommended to immerse the product in insulating oil to ensure the normal operation of the relay. When the product is used in the air, it shall be ensured that the product is used in a ventilated and dry environment to prevent the product from dirt deposition and moisture.
, structure and performance
The relay contact is in vacuum, with vacuum as the medium and ceramic as the shell. The surface of the porcelain is glazed, and the contact is made of high melting point metal. Therefore, the product has the characteristics of extremely high breakdown voltage, extremely fast dielectric recovery rate, no pollution of contacts, small and stable contact resistance, large rated current and breaking current, long service life, etc. The specific performance indicators of the relay are as follows:
1. Contact combination form: 1B (single pole single throw normally closed type)
2. Coil resistance: 120 Ω± 10% at +20 ℃
3. Rated working voltage of coil: 24V
4. Pull in voltage: max. 20V
5. Release voltage: minimum 1V
6. Pull in time: no more than 50ms
7. Rated working voltage: 90/150kv (DC or 50/60hzac peak)
8. Contact resistance: no more than 0.02 Ω
9. Insulation resistance: the insulation resistance of each unconnected conductive part shall not be less than 1000m Ω.
10. Load capacity: a) bearing current 10A (DC or 50/60hzac effective value);
b) Breaking 10A current (resistive load) at 240V effective value of 50/60hzac.
11. Service life: the mechanical service life of the product can reach 1 × 106 times; When 10A current is disconnected under power frequency 240V, the service life of the relay shall not be less than 2 × 104 times.

Price Terms︰FOB Wuxi
Specifications︰Product specification parameters
Relay rated parameters Company GT80B GT120B
Contact code B(1D) B(1D)
Contact form SPST-NC SPST-NC
Maximum test voltage (leakage current not exceeding 15 μ A. DC or 60Hz) kV Peak one hundred one hundred and fifty
Maximum operating voltage, contact to base (leakage current not exceeding 15 μ A) DC or 60Hz kV Peak eighty one hundred and twenty
2.5MHz kV Peak - -
16MHz kV Peak - -
32MHz kV Peak - -
Maximum continuous load current DC or 60Hz Amps twelve eight
2.5MHz Amps - -
16MHz Amps - -
32MHz Amps - -
Coil breakdown voltage (60Hz, AC effective value) V five hundred five hundred
Contact capacitance Between open contacts pF three three
Contact to ground pF three point five
Maximum contact resistance (1a, 28vdc) ohms zero point zero two
Maximum working time ms -
Maximum release time ms fifty
Mechanical life 1 × one hundred and six Cycles two
Nominal weight g three thousand and eight hundred
Vibration frequency (sinusoidal, 55~500 Hz, peak) G's 24.5(25)
Impact level (11ms, half sine wave, peak) G's 147(15)
Operating ambient temperature range ℃ - 55~+85
Advantages︰3. Gt80/120 ceramic vacuum relay (hereinafter referred to as relay) is mainly used as conversion or discharge element in various high-voltage equipment, high-voltage power supply and circuit.
5. The relay can operate normally under the following conditions:
a. Ambient temperature: -55 ℃ ~+85 ℃
b. 98% when relative humidity: +40 ℃
c. Atmospheric pressure: 650~800mmhg
d. Vibration: frequency 10~500hz, acceleration 2.5G
e. Impact: acceleration 15g
Export Markets︰It is mainly used as conversion or discharge element in various high-voltage equipment, high-voltage power supply and circuit
Payment Details︰Delivery upon payment
Min Order︰10
Ship Date︰two weeks later
Product Image





Related Products
GTD22 VACUUM RELAYS
GTD22 VACUUM RELAYS
US $ 380
Jpk-18 vacuum relay 15kV
Jpk-18 vacuum relay 15kV
US $ 300
JPK series vacuum relay 28kv
JPK series vacuum relay 28kv
US $ 480
JPK-2 series vacuum relay
JPK-2 series vacuum relay




Home  |  Product Catalog  |  Vacuum Relays Capacitor  |  DWC-series Electric Septic Cha  |  Glass TRIODE  |  HV Relay (Vacuum Relay)  |  company profile;  |  VACUUM TRIGGER TUBE  |  Documents  |  News  |  Contact Us  |  Sitemap  |  Mobile Version
  English     简体版     繁體版

Powered by DIYTrade.com  Build your FREE website !
Find Best Price For China Products !