GTVAC---DZCF2014 DZCF VACUUM TRIGGER TUBE

GTVAC---DZCF2014  DZCF VACUUM TRIGGER TUBE

Model No.︰GTVAC---DZCF201

Brand Name︰GTVAC

Country of Origin︰China

Unit Price︰-

Minimum Order︰10 pc

Inquire Now

Product Description

The vacuum trigger tube is a kind of fast pulse switches applicable for high voltage and current.It offers a number of advantages,such as high with stand voltage,small in size.no noise,fast ignition and fast recovery,etc.So,it is widely used as the HV,frequently-operated,pulse switch in the discharge units of a capacitor bank and the laser systems.

Price Terms︰ FOB Wuxi

Specifications︰ Product specifications
Model DZCF100/10 DZCF100/50
Rated working voltage (kV) fifty fifty
Peak current (KA) one hundred three hundred
Quantity of electricity (c) ten ten
Triggering energy (J) 0.1-1 0.1-1
Triggering voltage (kV) 3-10 3-15
Inductance (Uh) < zero point one < zero point one
Minimum operating voltage at gap
Min Working Voltageacross Mai Gap(V) < fifty < fifty
Voltage drop of tube (V) < fifty < fifty
Cutoff current (a) < ten < ten
Max working frequency (kHz) ten ten
Operating life (Times) > one hundred and four > one hundred and four
Triggering delay (US) zero point one zero point one
Delay dispersion (US) < zero point zero two < zero point zero two
Outline dimensions (mm) Ф eighty × one hundred and thirty-five Ф eighty × two hundred and fifteen
Weight (kg) one point five zero two
Self breakdown voltage (DC) 25kV-65kV
Self breakdown voltage tolerance (DC) 0~+10%
Operating voltage range (DC) 40~80% of self breakdown voltage
Trigger condition The minimum voltage is 1kV, and the voltage rise rate is greater than or equal to 15kV when the load is disconnected/ μ s. Trigger current is greater than 1.0A
Maximum peak current 100kA
Maximum discharge per time 0.5C
Total discharge capacity 16000c (16mc each time, 4 times per second, when the maximum current is 10kA)
Anode delay time Not more than 15 μ S (Note 1)
Operating temperature range - 40--+70℃
Mechanical impact 40g ,6ms
Installation direction arbitrarily
Nominal weight 1500g–2000g
Note 1: the typical time is the time between the trigger current reaching 90% of the trigger breakdown current and the anode reaching the maximum current when the working voltage is 10-35kV.

Advantages︰ The vacuum trigger tube is a kind of fast pulse switches applicable for high voltage and current.It offers a number of advantages,such as high with stand voltage,small in size.no noise,fast ignition and fast recovery,etc.So,it is widely used as the HV,frequently-operated,pulse switch in the discharge units of a capacitor bank and the laser systems.