This type of product adopts vacuum medium and ceramic shell, which has the reliable advantages of high pressure resistance, small volume, fast breaking speed and stable performance. It is widely used in the control circuits of radar, power supply, broadcasting, radio communication and electronic equipment.
The installation method is flange type and welded high-voltage joint. The wiring is simple. The coil can be replaced to diversify the product functions. It meets or exceeds the mil-r-83725 standard. For load switch application, please consult the factory!
Specifications︰
Relay rated parameters Company JPK-2/009 JPK-2/054
Contact code C
Contact form SPDT
Maximum test voltage (leakage current not exceeding 15 μ A. DC or 60Hz) kVPeak seventeen
Maximum operating voltage, contact to base (leakage current not exceeding 15 μ A) DC or 60Hz kVPeak fifteen
2.5MHz kVPeak twelve
16MHz kVPeak nine
32MHz kVPeak seven
Maximum continuous load current DC or 60Hz Amps fifty thirty
2.5MHz Amps thirty
16MHz Amps seventeen
32MHz Amps eight
Coil breakdown voltage (60Hz, AC effective value) V five hundred five hundred
Contact capacitance Between open contacts pF zero point five zero point five
Contact to ground pF one one
Maximum contact resistance (1a, 28vdc) ohms zero point zero two five zero point zero two five
Maximum working time ms fifteen fifteen
Maximum release time ms nine nine
Mechanical life Cycles 1 million
Nominal weight g (oz) 84(3)
Vibration frequency (sinusoidal, 55~500 Hz, peak) G's ten
Impact level (11ms, half sine wave, peak) G's fifty
Operating ambient temperature range ℃ - 55~+125
Advantages︰
Coil parameters
Nominal Voltage VDC twelve twenty-six point five one hundred and fifteen
Maximum pull in Voltage VDC eight sixteen eighty
Release Voltage VDC . 5-5 1-10 5-50
Coil resistance (Ω± 10%) forty-eight one hundred and eighty two thousand and nine hundred
*The above data are measured at 25 ℃ and sea level