GTVAC---DZCF902 VACUUM TRIGGER TUBE

GTVAC---DZCF902 VACUUM TRIGGER TUBE

Model No.︰GTVAC---DZCF902

Brand Name︰GTVAC

Country of Origin︰China

Unit Price︰-

Minimum Order︰10 pc

Inquire Now

Product Description

Model
DZCF901/10
DZCF902/50
Rated working voltage (kV)
fifty
fifty
Peak current (KA)
twenty-five
fifty
Quantity of electricity (c)
ten
ten
Triggering energy (J)
0.1-1
0.1-1
Triggering voltage (kV)
3-10
3-15
Inductance (Uh)
<0.1
<0.1
Minimum operating voltage at gap
Min Working Voltageacross Mai Gap(V)
<50
<50
Voltage drop of tube (V)
<50
<50
Cutoff current (a)
<10
<10
Max working frequency (kHz)
ten
ten
Operating life (Times)
>104
>104
Triggering delay (US)
zero point one
zero point one
Delay dispersion (US)
<0.01
<0.02
Outline dimensions (mm)
Ф sixty-nine × one hundred and fifty-five
Ф sixty-nine × one hundred and fifty-five
Weight (kg)
one point two zero
one point five zero
Note 1: the typical time is the time between the trigger current reaching 90% of the trigger breakdown current and the anode reaching the maximum current when the working voltage is 10-35kV.

Specifications︰ Product specifications
Model DZCF901/10 DZCF902/50
Rated working voltage (kV) fifty fifty
Peak current (KA) twenty-five fifty
Quantity of electricity (c) ten ten
Triggering energy (J) 0.1-1 0.1-1
Triggering voltage (kV) 3-10 3-15
Inductance (Uh) < zero point one < zero point one
Minimum operating voltage at gap
Min Working Voltageacross Mai Gap(V) < fifty < fifty
Voltage drop of tube (V) < fifty < fifty
Cutoff current (a) < ten < ten
Max working frequency (kHz) ten ten
Operating life (Times) > one hundred and four > one hundred and four
Triggering delay (US) zero point one zero point one
Delay dispersion (US) < zero point zero one < zero point zero two
Outline dimensions (mm) Ф sixty-nine × one hundred and fifty-five Ф sixty-nine × one hundred and fifty-five
Weight (kg) one point two zero one point five zero
Note 1: the typical time is the time between the trigger current reaching 90% of the trigger breakdown current and the anode reaching the maximum current when the working voltage is 10-35kV.

Advantages︰ Vacuum trigger tube is a high voltage, high current fast pulse switch. It has the advantages of high pressure resistance, small size, no noise, rapid ignition and rapid recovery. It is widely used in capacitor bank discharge devices. High voltage and high repetition rate pulse switches are used in the laser system.