Product Description

Coil parameters
Nominal Voltage VDC
twelve
twenty-six point five
one hundred and fifteen
Maximum pull in Voltage VDC
eight
sixteen
eighty
Release Voltage VDC
. 5-5
1-10
5-50
Coil resistance (Ω± 10%)
eighty
three hundred and thirty-five
six thousand
*The above data are measured at 25 ℃ and sea level

Price Terms︰ FOB Wuxi

Specifications︰ Product specification parameters
Relay rated parameters Company GTH2 GTH4 GTH6
Contact code C C C
Contact form SPDT SPDT SPDT
Maximum test voltage (leakage current not exceeding 15 μ A. DC or 60Hz) kV Peak ten ten ten
Maximum operating voltage, contact to base (leakage current not exceeding 15 μ A) DC or 60Hz kV Peak eight eight eight
2.5MHz kV Peak - - -
16MHz kV Peak - - -
32MHz kV Peak - - -
Maximum continuous load current DC or 60Hz Amps twenty-five fifteen eight
2.5MHz Amps - - -
16MHz Amps - - -
32MHz Amps - - -
Coil breakdown voltage (60Hz, AC effective value) V five hundred five hundred five hundred
Contact capacitance Between open contacts pF - - -
Contact to ground pF - - -
Maximum contact resistance (1a, 28vdc) ohms zero point zero one zero point zero two zero point five zero
Maximum working time ms six six six
Maximum release time ms six six six
Mechanical life Cycles 2 million 2 million 1 million
Nominal weight g (oz) 28(1) 28(1) 28(1)
Vibration frequency (sinusoidal, 55~500 Hz, peak) G's ten ten ten
Impact level (11ms, half sine wave, peak) G's fifty fifty fifty
Operating ambient temperature range ℃ - 55~+125 - 55~+125 - 55~+125

Advantages︰ GTH 8Kv series
Small size, 8Kv relay, screw sleeve type, easy to install, user can change the coil, so that the product has diversified functions, meeting or exceeding the mil-r-83725 standard
GtH2 non load switch gth4 is used to make and break loads
Low contact resistance and stable wear-resistant tungsten contact, suitable for frequent operation occasions
High load current, continuous DC 25A, compact vacuum medium, effective arc extinguishing when disconnected under load
Gth6 for closing load
It is extremely suitable for capacitor discharge and safety unloading switch applications. It can be made according to the actual needs of customers. For load switch applications, please consult the factory

Export Markets︰ Switching power supply, contact discharge, capacitor discharge