GTH 8kVSeriesHV Relays

GTH 8kVSeriesHV Relays

Model No.︰GTH2、GTH4、GTH6

Brand Name︰GTVAC

Country of Origin︰China

Unit Price︰CNY ¥ 1080 / pc

Minimum Order︰1 pc

Inquire Now

Product Description

GTH 8kV Series

Easy to mount threaded base with jam nut

User interchangeable coils provide for driver versatility

Meets or exceeds standards set in MIL-R-83725

GTH2 No Load Switching

Low, stable contact resistance minimizes voltage drop in sensitive circuits

High carry current, 25Adc continuous, in a small package

GTH4 Make & Break Load Switching

Durable tungsten contacts for hot load switching

Vacuum dielectric for effective arc quenching when opening under load

GTH6 Make Only Load Switching

Excellent for capacitive discharge and safety dump switch applications

Can be modified to accommodate customer specified cables and connectors

Consult factory for load switching applications

 

 

Product Specification

Contact & Relay Ratings

Units

GTH2

GTH4

GTH6

Contact Form

 

C

C

C

Contact Arrangement

 

SPDT

SPDT

SPDT

Test Voltag,(kV, Peak), Test Max., Contacts & to Base (15 μA Leakage Max., dc or 60Hz)

kV Peak

10

10

10

Rated Operating Voltage,(kV,Peak), Contacts & to Base (15 μA Leakage Max.)

dc or 60Hz

kV Peak

8

8

8

2.5MHz

kVPeak

-

-

-

16MHz

kV Peak

-

-

-

32MHz

kV Peak

-

-

-

Continuous Current, Carry Max

dc or 60Hz

Amps

25

15

8

2.5MHz

Amps

-

-

-

16MHz

Amps

-

-

-

32MHz

Amps

-

-

-

Coil Hi-Pot (V RMS, 60 Hz)

V

500

500

500

Capacitance

Across Open Contacts

pF

-

-

-

Contacts to Ground

pF

-

-

-

Resistance, Contact Max @ 1A, 28Vdc

ohms

0.01

0.02

0.50

Operate Time, Max

ms

6

6

6

Release Time, Max

ms

6

6

6

Mechanical Life

Cycles

2 million

2 million

1 million

Weight

g(02)

39(1)

39(1)

39(1)

Vibration, Sine (10-2000 Hz Peak)

G's

10

10

10

Shock, 1/2 Sine11ms (Peak)

G's

50

50

50

Operating Temperature Ambient

°C

-55  +125

-55  +125

-55  +125

Coil Ratings

Nominal, Volts dc

12

26.5

115

Pick-up, Volts dc, Max

8

16

80

Drop-Out, Volts dc

.5-5

1-10

5-50

Coil Resistance(Ω±10%)

80

335

6000

* Ratings listed are for 25°C, sea level conditions

 

 

 

 

For more information, refer to
Relay User Instructions

 

GTH      2    12VDC

 

 

 

Model
 2 
 4 
 6 

 

 CoilVoltage 
 12Vdc = 12 Vdc,

 Blank = 26.5 Vdc, 

115 = 115 Vdc,

 

Order the relay with the coil voltage in the part number as shown above.

The coil voltage will appear on the coil plate near the coil terminals rather than in the P/N on the relay.

 

Price Terms︰ FOBWuxi

Specifications︰ GTH 8kV
GTH2,GTH4,GTH6

Advantages︰ GTH 8kV Series
Easy to mount threaded base with jam nut
User interchangeable coils provide for driver versatility
Meets or exceeds standards set in MIL-R-83725
GTH2 No Load Switching
Low, stable contact resistance minimizes voltage drop in sensitive circuits
High carry current, 25Adc continuous, in a small package
GTH4 Make & Break Load Switching
Durable tungsten contacts for hot load switching
Vacuum dielectric for effective arc quenching when opening under load
GTH6 Make Only Load Switching
Excellent for capacitive discharge and safety dump switch applications
Can be modified to accommodate customer specified cables and connectors
Consult factory for load switching applications

Pricing︰ 1080

Payment Details︰ Arrival and delivery

Min Order︰ 1

Ship Date︰ 1-4 weeks

Standard Met︰ Meet or exceed MIL-R-83725 standard.

Product Image